14
Month max interval
HSG258
HSE guidance
COSHH
Reg 9 duty
LEV / COSHH CAPTURE HOOD PROCESS m/s FACE VELOCITY EXAMINE · MEASURE · REPORT
TExT to HSG258 Full LEV report Pass/fail labelling Fully insured Nationwide

Southampton

Where fume and dust control sits in Southampton

Southampton is the UK's cruise capital - the port handled a record 3 million passengers in 2024 - and a working city of around 249,000.

The heavy work is on the water - the ship repair and superyacht build along the docks, the marine and composite boatbuilding, and the port and food-distribution operations - with the fabrication, bodyshops and university labs of the Nursling and Millbrook estates around them.

Each of those Southampton processes throws fume, dust, mist or vapour into the workplace air, and COSHH demands it is captured at source - that capture system is local exhaust ventilation, and it must be thoroughly examined and tested at least every fourteen months. We cover the lot, from the Nursling units to the one-bench Southampton workshops, taking capture and face-velocity readings and leaving a clear pass or remedial verdict with the hoods labelled.

By sector

The Southampton workplaces that need an LEV test

A system that catches fume, dust, mist or vapour at the point it is released is LEV, and for Southampton employers and others across Hampshire it is the record COSHH looks for first.

Marine and port engineering

Fume and grinding extraction across the ship-repair and workboat-build units along the docks, where heavy welding fume needs capture at source.

Marine composites and boatbuilding

Resin-fume, laminating and spray extraction on the GRP and superyacht lines, where composite dust and vapour need capture proven.

Welding and fabrication

On-torch extraction, fume arms and downdraught benches across the fabrication units. Since the HSE's 2019 reclassification, all welding fume - mild steel included - is treated as carcinogenic.

Vehicle body and paint

Spray-booth and prep-bay extraction at Southampton bodyshops. Two-pack paints release isocyanates - the leading cause of occupational asthma - so booth airflow is examined to its design figure.

Food and drink distribution

Extraction and dust control across the port-linked food and drink handling and distribution operations.

Labs and fume cupboards

Fume-cupboard face-velocity testing for the two universities and Southampton General Hospital, to the containment their work demands.

On the ground in Southampton

What we have tested across the city

We are out under Southampton's extraction every week. The proof that matters is the jobs, not a stock photo.

A port grain-storage silo complex in Southampton had the dust-suppression extraction at the main conveyor drop-point losing 35% of its static pressure - an inspection hatch had been left unsealed. We fitted a new gasket to seal the hatch, ran a full pitot-tube airflow traverse and measured the static pressure. It passed once the seal was renewed, with the transport velocity back up to 21 metres per second to stop the dust settling. It was an ATEX Zone 20 area, so it was all done on non-sparking brass tools and intrinsically safe gear.

The test

What a thorough examination and test measures in Southampton

Under HSG258 a statutory LEV test is no visual once-over. For a Southampton system it has to answer three things - whether the system is sound, whether it still draws at the hood, and whether that draw holds to what it was designed to deliver.

Visual and structural

Ductwork, hoods, filters, fans and dampers checked for damage, blockage and leakage across the Nursling units - the faults that quietly kill capture.

Quantitative performance

Face and capture velocities, static pressures and airflows measured at each hood with calibrated instruments - numbers, not opinion.

Benchmark to design

Readings compared to the system's commissioning figures, so drift from as-designed is caught before it becomes a failure on a Southampton line.

Air sampling, where needed

Where exposure is in question - a marine and port engineering process, say - sampling confirms whether control is actually protecting the people at the process.

The duty

Fourteen months, and whose name is on it

COSHH Regulation 9 puts a hard duty on the employer: any LEV controlling a hazardous substance must have a thorough examination and test at least every fourteen months, with records kept for five years.

For the great majority of Southampton sites, from the Nursling units to the one-man workshops, the fourteen-month deadline is what catches people out: once it passes the system is non-compliant regardless of its actual state. We carry out the examination, label every hood with its status and next-due date, and issue the report an HSE inspector or your insurer expects to see - and if a point fails, you get the number, the cause and the fix rather than a bare fail.

How it runs

Examine, measure, report, label

1

Examine

Full visual and structural check of every hood, duct run, filter and fan across the Southampton site.

2

Measure

Calibrated velocity, pressure and airflow readings at each extraction point.

3

Report

A COSHH-compliant report: results against benchmark, clear pass or fail, and plain-English actions for the Southampton duty-holder.

4

Label

Each system tagged with status and next-due date, so compliance is visible on the Millbrook floor.

Questions

Frequently asked questions

How often does LEV need testing in Southampton?

Under COSHH Regulation 9, most local exhaust ventilation needs a thorough examination and test at least every 14 months, with higher-risk processes more often. A marine and port engineering bay, a marine composites and boatbuilding bench and a lab fume cupboard can each sit on a different interval - we set the right one for every system.

Do you cover Nursling, the city and the rest of Southampton?

Yes - the industrial estates and workshops around Nursling and Millbrook, the university and hospital labs, and the wider Hampshire.

Can you commission a newly installed LEV system?

Yes. A new spray booth or fume-arm install at a Southampton workshop needs a commissioning test to prove it performs to its design figures before it goes into service - we measure it and document the baseline the 14-month clock then runs from.

Do you provide the LEV logbook and labelling?

Yes. Each hood is labelled with its status and next-due date, and you get the HSG258 report and system schematic for your COSHH file - the record an HSE inspector visiting a Nursling unit will ask to see.

Is LEV testing the same as TR19 grease cleaning?

No. LEV testing is a statutory examination of fume and dust control to COSHH and HSG258, with capture and face-velocity readings; TR19 is kitchen grease and fire risk. We do both across Southampton, but a Nursling fabrication shop and a Bevois Valley canopy are kept as the separate jobs they are.

What do we get after the test?

A dated report to the HSG258 method, the readings taken, a pass or remedial outcome for each hood, and system labelling - the evidence a duty-holder at Nursling or a smaller Southampton workshop needs for their COSHH file.

Which Southampton industries need LEV testing?

Marine and port engineering, marine composites and boatbuilding, welding and fabrication, vehicle body and paint, food and drink distribution, and the labs of the universities and hospital - the trades clustered around Nursling and Millbrook and across the wider Hampshire.

20+ Years of Experience

Phoenix Duct Clean · by the numbers

LEV systems
tested
1,658
Kitchen canopies
degreased
4,287
Laundry ducts
cleaned
1,877
Hours
on site
54,754

Book your LEV thorough examination

Stay compliant with COSHH and HSG258. No-obligation quote, UK-wide.