Statutory thorough examination and testing of local exhaust ventilation for Neston workshops and production sites, keeping fume and dust control compliant with COSHH and HSE guidance HSG258.
Neston
Neston is a small market town of some fifteen thousand people at the southern tip of the Wirral, set on the eastern bank of the Dee Estuary with the Welsh shore across the water - and the birthplace, at Ness in 1765, of Emma Lyon, the blacksmith's daughter who grew up to become Nelson's Lady Hamilton. It was a working port for the Irish crossing before the Dee silted and the trade drifted downstream to Parkgate and then away to Liverpool.
Its working economy today runs on engineering, food production and the fabrication trades, much of it grouped in the light-industrial units at the Clayhill Industrial Park and Millennium Court off Liverpool Road, within reach of the wider Deeside and Ellesmere Port industrial belt across the peninsula.
Every Neston process that gives off fume, dust, mist or vapour falls under COSHH, which requires the contamination held at source by local exhaust ventilation and that LEV thoroughly examined and tested at least every fourteen months. We test right across the site, from the Clayhill Industrial Park plant to the single-bench Neston units, logging capture and face-velocity figures and returning a clear pass-or-remedial outcome with each hood identified and labelled.
By sector
A system that catches fume, dust, mist or vapour at the point it is released is LEV, and for Neston employers and others across Cheshire it is the record COSHH looks for first.
Oil-mist and coolant-mist extraction on CNC machining centres and turning shops across the Clayhill Industrial Park and Millennium Court units, in a town whose collieries once cut coal from seams that ran clean out under the Dee.
Steam canopies, oven extraction and flour-dust control in Neston's bakeries and food businesses and the produce trades that supply the town's market and the farms around Burton and Willaston.
Fine-dust extraction and downdraught tables at Neston cabinet shops and joinery works, where hardwood and MDF dust is captured at the tool before it can reach the lungs.
On-torch extraction, fume arms and downdraught benches across the steel fabricators and workshops of the Clayhill Industrial Park and Millennium Court. Since the HSE's 2019 reclassification, all welding fume - mild steel included - is treated as carcinogenic.
Spray-booth and prep-bay extraction at Neston bodyshops and the agricultural engineering yards that serve the surrounding Wirral farms. Two-pack paints release isocyanates - the leading cause of occupational asthma - so booth airflow is examined to its design figure.
Fume-cupboard and glasshouse extraction testing for the research collections and teaching labs at Ness Botanic Gardens, run by the University of Liverpool, and the science rooms of Neston High School, to the containment their work demands.
On the ground in Neston
We are out under Neston's extraction every week. The proof that matters is the jobs, not a stock photo.
The weld-fume extraction on the exhaust bay at a family-owned Neston vehicle workshop wasn't pulling as it should, down to a filter well overdue for replacement. I checked the static pressure, sorted the worn impeller and re-tested each point against the benchmark. One point failed initially on a slipping belt and passed after the remedial work, all set out in a full LEV report for the COSHH file. The owner kept us going with fresh coffee through the morning.
The test
An HSG258 statutory LEV test goes well beyond a walk-round look. On a Neston system it has to establish three things - that the plant and ductwork are sound, that the hoods still capture, and that the capture still meets the figure the system was designed around.
Ductwork, hoods, filters, fans and dampers checked for damage, blockage and leakage across the Clayhill Industrial Park units - the faults that quietly kill capture.
Face and capture velocities, static pressures and airflows measured at each hood with calibrated instruments - numbers, not opinion.
Readings compared to the system's commissioning figures, so drift from as-designed is caught before it becomes a failure on a Neston line.
Where exposure is in question - a precision engineering and manufacturing process, say - sampling confirms whether control is actually protecting the people at the process.
The duty
Under Regulation 9 of COSHH the obligation sits squarely with the employer - any LEV that controls a hazardous substance needs a thorough examination and test at least every fourteen months, and the records held for five years.
On most Neston sites - the Clayhill Industrial Park units and the smaller workshops alike - it is the fourteen-month clock that bites: let it lapse and the system is non-compliant that day, however well it seems to run. We examine it, tag each hood with its status and next-due date, and hand over the report an HSE inspector or insurer will want. Where something fails you get the reading, the cause and the remedy - never just a red sticker.
How it runs
Full visual and structural check of every hood, duct run, filter and fan across the Neston site.
Calibrated velocity, pressure and airflow readings at each extraction point.
A COSHH-compliant report: results against benchmark, clear pass or fail, and plain-English actions for the Neston duty-holder.
Each system tagged with status and next-due date, so compliance is visible on the Millennium Court floor.
Questions
Under COSHH Regulation 9, most local exhaust ventilation needs a thorough examination and test at least every 14 months, with higher-risk processes more often. A precision engineering and manufacturing bay, a food and drink production bench and a lab fume cupboard can each sit on a different interval - we set the right one for every system.
Yes. A new spray booth or fume-arm install at a Neston workshop needs a commissioning test to prove it performs to its design figures before it goes into service - we measure it and document the baseline the 14-month clock then runs from.
No. LEV testing is a statutory examination of fume and dust control to COSHH and HSG258, with capture and face-velocity readings; TR19 is kitchen grease and fire risk. We do both across Neston, but a Clayhill Industrial Park fabrication shop and a Mellock Lane canopy are kept as the separate jobs they are.
Yes. We plan testing around production shifts at the Clayhill Industrial Park units, term-time access at the Neston university labs, and normal hours at smaller workshops, so the examination never stops the line.
A dated report to the HSG258 method, the readings taken, a pass or remedial outcome for each hood, and system labelling - the evidence a duty-holder at Clayhill Industrial Park or a smaller Neston workshop needs for their COSHH file.
Yes - the industrial estates and workshops around Clayhill Industrial Park and Millennium Court, the university and hospital labs, and the wider Cheshire.
We record it as remedial and set out what is needed - airflow, ductwork, filtration or capture at the hood. You do the work and we re-test, and on a Clayhill Industrial Park production line we can usually fit the re-test around your shifts. We will not pass a system that does not control exposure.
Local knowledge
Coal was mined at Ness and Little Neston from 1759, the Ness Colliery working seams that ran out under the Dee Estuary itself and floating boats of coal along canals cut deep underground. A second phase opened in 1875 as Neston Colliery, later Wirral Colliery, served by a branch off the Parkgate railway until competition from bigger pits closed it in 1927. That heavy-industry inheritance survives in the machine shops and workshops of the Clayhill Industrial Park today, each carrying a duty to control the mist, fume and dust its work throws off. We test and certify local exhaust ventilation to the standard COSHH sets, so the extraction reads true against its design figures.