Food and Drink Production: LEV for Flour, Steam and Fumes

Behind familiar ingredients sit real respiratory hazards. Flour dust and process fumes need extraction - and the extraction needs testing like any other LEV.

Flour
10 mg/m3 WEL
STEL
30 mg/m3 15 min
ALARP
Below 2 mg/m3
Sensitiser
Occupational asthma
At source
Capture
14 months
Test interval
CAPTUREFLOUR
TR19 certificate Before & after photos Filters degreased Fully insured EHO accepted

The short answer

Food production has real respiratory hazards, and LEV is how they are controlled

Food and drink production looks low-risk, but it hides genuine airborne hazards: flour and grain dust that can cause occupational asthma, process fumes from cooking and frying, and steam that carries other contaminants. Flour dust in particular is a hazardous substance under COSHH with an enforced exposure limit. Local exhaust ventilation controls these at source, and like any LEV it has to be tested to prove it is working.

The detail

Flour dust and the numbers

Flour dust has a workplace exposure limit made up of a long-term limit of 10 mg per cubic metre averaged over eight hours and a short-term limit of 30 mg per cubic metre over fifteen minutes. But those figures are a ceiling, not a target. Flour dust is a respiratory sensitiser - an asthmagen - so exposure must be reduced as far below the limit as reasonably practicable; the HSE considers that good practice should get exposure below 2 mg per cubic metre. Flour dust and the enzymes in bread improvers are among the most common causes of occupational asthma in the country.

The hazard is not limited to flour. Many food dusts - spices, custard and soup powders, dried milk, sugar - behave similarly, and some are also explosion risks in quantity. Cooking and process fumes add another exposure. The common thread is that the control is extraction at the point the dust or fume is generated: at the tipping point, the mixer, the process vessel or the cook line, drawing the contaminant away before it reaches the operator.

What it means for you

What a test checks in a food environment

A thorough examination and test of food-production LEV checks that each capture point is drawing the dust or fume away effectively, that the ducts and fan are moving air at the commissioned rate, and that filters and collectors are sound - at least every fourteen months. Food settings add their own wrinkles: extraction has to cope with a mix of dry dust and moist, steam-laden air, and hygiene requirements mean ducts and hoods need to stay cleanable as well as effective.

The usual failing is a capture hood that no longer draws enough air over a busy tipping or mixing operation, so a visible haze of flour builds in the operator's breathing zone. Because sensitisation can be triggered at low exposures and is often permanent, keeping that capture proven and effective is what protects a workforce that may otherwise have to leave the trade.

Below 2
mg/m3 target
Asthmagen
Reduce ALARP
At source
Every point

The service behind the guide

Extraction that keeps the line safe to breathe

We test LEV across flour handling, process fumes and steam, and report on capture, airflow and any remedial work, so your food environment controls exposure at source.

Questions

Frequently asked questions

What is the exposure limit for flour dust?

Flour dust has a long-term limit of 10 mg per cubic metre over eight hours and a short-term limit of 30 mg per cubic metre over fifteen minutes. As it is an asthmagen, exposure should be reduced well below this - below 2 mg per cubic metre with good practice.

Why does food production need LEV?

Because flour and grain dust, process fumes and steam-borne contaminants are genuine respiratory hazards. LEV captures them at source, and flour dust is a hazardous substance controlled under COSHH.

Is flour dust really a serious hazard?

Yes. Flour dust and the enzymes in bread improvers are among the most common causes of occupational asthma in the UK, and sensitisation can be triggered at low exposures and is often permanent.

What makes food-environment LEV different to test?

It often has to handle a mix of dry dust and moist, steam-laden air, and hygiene requirements mean ducts and hoods must stay cleanable as well as effective, which the examination takes into account.

How often should the extraction be tested?

At least every fourteen months under COSHH, with weekly user checks in between, so capture and airflow are proven against the commissioning benchmark.

20+ Years of Experience

Phoenix Duct Clean · by the numbers

Kitchen canopies
degreased
4,287
Laundry ducts
cleaned
1,877
LEV systems
tested
1,658
Hours
on site
54,754

Test the extraction across your food line

We examine LEV on food and drink production - flour handling, process fumes and steam - and report clearly on control. Call or email to book.